As HERS raters we provide third party verification for home and business owners to test duct leakage, refrigerant charge and in some cases airflow and energy use. HERS verifications are also needed to complete building permits in certain cases. If you don't know which verifications you need, give us a call at 1-800-597-7153 and we can walk you through the process.
On January 1st, 2010 new Title 24, building code standards came into effect. HERS ratings are required in most cases to at least verify duct leakage or refrigerant charge. According to the California Energy Commission, the average duct system leaks 30% in CA homes. So if you are a home owner you want to make sure your system is not leaking and as a contractor you can tell customers that duct leakage will be verified by a third party to ensure quality.
To find out your climate zone or if HERS ratings are requred for your HVAC work select read more...
How to find your climate zone
for commercial jobs climate zones do not apply
For residential jobs you will need to know the Climate Zone (CZ) your home/job is in.
To find your Climate Zone enter the address ( 411 HERS Rd. Title24 Town, CA) in the space provided above the map and click the goto! button . Once the map zooms to where your home or job is click the color area around the home. It will say Outline zn then a number. That number is your climate zone,
HERS tests are required in Climate Zones 2 and 8 - 16.
This map is from the Energy Maps of California.
For non-residential jobs the climate zone does not apply but jobs you will need a HERS rating if you meet requirements listed below.
Call: 1-800-597-7153
We can provide the HERS verifications you need to keep your project moving.
Below is a list of reasons you may need a HERS rating.
Skip to Commercial Requirements
HERS verification MAY BE required if your residential job:
- Is in Climate zone, 2, or 8 - 16 (Go back to check climate zone)
- Is Asbestos Free
- Has a duct length in unconditioned space of 40 feet or more
AND your job includes any of the following change outs:
- Replacement of Package Unit
- Complete replacement of split system (HVAC Unit)
- Furnace/Air Handler
- Cooling or Heating coil
- Furnace Heat Exchanger
- Outdoor condensing unit
- Heat Pump
- Adding or replacing 40 feet or more of duct work
If your job falls into this category then duct testing and refrigerant charge measurement may be required. If a new HVAC equipment and new duct work is installed then an airflow measurement and fan watt draw may also be required.
Download a brochure with this information.
Visit our List of Services to find out current prices for verifications.
If your Commercial Job:
- Is Asbestos free
- More than 25% of Duct Surface Area is in unconditioned space or outdoors
- System is a Constant Volume System (NO VAV Installed)
- Single unit services 5,000 sq. ft. or less
-
Applies to all climate zones
And your work includes any of the following:
- Replacement of Package Unit
- Complete Replacement of Split System (HVAC Unit)
- Furnace/Air Handler
- Cooling or Heating Coil
- Furnace Heat Exchanger
- Outdoor Condensing Unit (Split System)
- Heat Pump
- Adding any length of ducting that causes the Duct Surface Area in unconditioned space to exceed 25%
Download a brochure with the commercial requirements.
Contact us for HERS Verification services, 800-597-7153 or email info@aae-hers.com